Horizontal split case pumps are in-line pumps in which the pump housing is divided axially into two parts. Horizontal split case pumps are characterised by their high efficiency and low noise levels, as well as how easy they are to service. The pumps are designed to work in a variety of applications, including public water supply, district cooling and HVAC systems.
Learn MoreHorizontal split case pumps are easy for maintenance as the top half of the casing can be removed, so the internal components (Bearing,
Learn Moremaintenance instructions for pumps in the KBL Thrustream. Extended range of horizontal split case centrifugal pumps for general water and industrial use.
Learn MorePatterson Horizontal Split Case Pump (HSC) Product Details, Request a Quote, Weinman L & LVM Horizontal Split Case Pump, Product Details, Request a Quote, Headquarters and Service Center, Service Center, 12265 Nicollet Avenue, Burnsville, MN 55337, 800-776-4425, Service Center, 26489 Industrial Blvd, Cohasset, MN 55721, 800-776-4425,
Learn MoreAurora 420 Series Split Case Pump Brochure; Aurora Models 421, 422, 423, & 485 Horizontal & Vertical Two-Stage Pumps Manual; Aurora Model 420 Series Engineering Data Guide; Aurora 420 Series- Two Stage Vertical & Horizontal Split Case Pumps Repair Parts Index; Aurora Repair Part Kits, Packing Kits, Seal Kits, Rotating Assemblies & Power Frame
Learn More2800 Horiontal Split-ase Pumps Installation Operation and Maintenance 1 Your Fairbanks Nijhuis™ 2800 is a split-case pump with the casing split on the horizontal centerline. This new compact design, with a shorter bearing span, has less deflection under hydraulic load, which results in less we the sleeves, bearings and packing.
Learn MoreThe GSC Series Pumps are horizontal double suction split casing pumps which This safety alert symbol will be used in this manual and on the pump safety
Learn MoreThe Split Case Pump casing is split horizontally or vertically depending on the type of pump, for maintenance. Suction and discharge flanges are opposed to each other. Usually designed to mount horizontally but may also be designed for vertical installation, hence Horizontal Split Case Pump or Vertical Split Case Pump.
Learn MoreThe MegaMachines HS horizontal split case pump is a single-stage, non-self-priming, between bearing, centrifugal volute pump. The independent bearing housing allows for ease of maintenance without removing the top casing. The double volute design reduces the radial load on the shaft, extending component life, minimising vibration and
Learn Moremaintenance and operation near the pump. These are general instructions and may not take into account local regulations. The user should ensure such regulations are 4.2 Type key for horizontal split case fire pump 7 5. Installation 9 5.1 Factory support 9 5.2 Location 9 5.3 Foundation 9 5.4 Rigging and lifting 10
Learn MoreRotating element or moving part This casing is split along the horizontal centerline of the pump shaft, suction and discharge nozzles both being located in the lower half. With this arrangement, it is not necessary to disconnect suction or discharge piping to make repairs to, or replace the rotating element.
Learn MoreProper Maintenance With the pump apart and the rotor removed, make sure the casing mating surfaces are properly prepared. I often see this step shortened or omitted, which will lead to premature casing leaks and more expensive repairs. The majority of casings are manufactured flat on both halves.
Learn MoreThe Split Case Pump casing is split horizontally or vertically depending on the type of pump, for maintenance. Suction and discharge flanges are opposed to each other. Usually designed to mount horizontally but may also be designed for vertical installation, hence Horizontal Split Case Pump or Vertical Split Case Pump. Features,
Learn MoreThe Split Case Pump casing is split horizontally or vertically depending on the type of pump, for maintenance. Suction and discharge flanges are opposed to each other. Usually designed to mount horizontally but may also be designed for vertical installation, hence Horizontal Split Case Pump or Vertical Split Case Pump. Features
Learn Moreugal Pumps for General Refinery Service," was developed a rangement is the horizontal split case double-suction pump. (Figure 5).
Learn MoreHORIZONTAL SPLIT. CASING PUMP. OPERATION &. MAINTENANCE MANUAL. A Mark of Quality MBH make horizontal split casing type pumps with suction and discharge.
Learn MoreThis feature permits easy removal of the rotating assembly for maintenance work without disconnecting the suction and discharge pipe lines. FLOWMORE Horizontal
Learn More2800 Horiontal Split-ase Pumps Installation Operation and Maintenance 13 Regreasable bearings will require periodic lubrication and this can be accomplished by using the zerk or lubrication fitting at each bearing. Lubricate the bearings at regular intervals using high quality grease.
Learn MoreAlso, LR Type horizontal split-case pumps are designed to ensure ease of maintenance and parts interchangeability. This means additional savings.
Learn MoreAdjust the metal supports or wedges until the shafts of the pump and driver are level. Check the coupling faces, as well as the suction and discharge flanges of the pump for horizontal or vertical position by means of a level. Correct the positions, if necessary, by adjusting the supports or wedges under the baseplate, as required. Figure 1.
Learn MoreSplit Casing Pump Troubleshooting Guide ; Bearings Overheating · Insufficient lubrication or lubricating oil / grease dirty or contaminated. Check
Learn More4600 Horizontal Split-Case. Base-Mounted Pumps. The Armstrong 4600 horizontal split-case (HSC) double suction pumps are base mounted and engineered to substantially reduce cost over rival designs across installation, operation, and lifetime maintenance. High-efficiency NEMA-premium motors ensure low energy consumption and cost.
Learn Moreyour Weinman representative or Crane Pumps & Systems Inc., Service Department in Piqua, Ohio, telephone (937) 778-8947 or Crane Pumps & Systems Canada, Inc., Brampton, Ontario, (905) 457-6223. INSTALLATION 1. FOUNDATION The pump foundation should be sufficiently substantial to form a level, rigid support for the combined weight
Learn MoreThe environmental-friendly split case pump has low maintenance requirements and can be produced in a number of materials according to the specific application requirements. Split case pumps are available for a wide range of flow rates and pressure heads. Available in horizontal and vertical execution and one or two-stage. CONFIGURATION Horizontal:
Learn MoreMBH make horizontal split casing type pumps with suction and discharge nozzles and their supporting feet integrally cast in the lower half casing. This construction allows removal of the
Learn MoreSpecifications Get Aurora Horizontal Split Case Fire Pumps fast through our Red Hot Shipping Program. KEY FEATURES UL Listed/FM Approved/NFPA-20 Design For Commercial, Industrial and Marine Use Diesel and Electric Driven Available Lower Initial Cost Quicker Delivery with Red Hot Quick Ship Program Ease of Maintenance Size and configure Aurora pumps
Learn MoreThis manual explains the installation, operation, and maintenance of Patterson Pump horizontal split case (HSC) pumps. This pump is a centrifugal, single-stage, double suction type. When properly installed and when given reasonable care and maintenance, centrifugal pumps should operate satisfactorily for a long period of time.
Learn MoreFeatures. - PD Split-case pumps are single stage, double suction centrifugal pumps. These pumps ensure a long service life, high efficiency, low operations cost, friendly maintenance and service. - PD pump casings, are split along the shaft axis and allow easy inspection and replacement of the rotating parts.
Learn MoreInternally Self-flushing Mechanical Seals. Broad Hydraulic Coverage. 416SS High Strength Shaft. Ease of Maintenance. Bearings Can Be Serviced Without Distur Upper Casing Half, Piping Connections or Motor Connection. NSF Certified. These pumps are perfect for high flow, high pressure water park applications.
Learn MoreVertical split case pumps are typically used in industrial applications like oil and water supply, ballast, and cooling. On the other hand, horizontal split case pumps are the most common and used for pumping low viscosity fluids at low to medium pressure, like water. Hence, these types of split case pumps are used in municipal pumping stations
Learn MoreNever do maintenance work on the pump when it is connected to the power supply. WARNING Automatic startup Death or serious personal injury ‐ Before any inspection, maintenance,
Learn More