UL Design. Head of Wall Firestop System. Page. Detail No. Title. SW Series - Shaftwall Assemblies 09 21 16.23. SW 101. 1 Hour Shaftwall Partition.
Learn MoreWall Assemblies USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and
Learn MoreUSG's range of resources on UL wall assemblies can help with the planning and Shaft Wall - Steel Stud (Non-Load-Bearing). Fire Rating. 1 hours.
Learn MoreFor 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. 608-274-4849 Contact SBCA 2701 E. 1 hour
Learn More7/12 · Just build a one hour wall against the exiting. Not sure if I will describe it correctly, but find a UL or other approved one hour listed design. Just start with half the rated wall against the existing wall, add the studs or built it on the ground and stand it, than add the other layer of sheet rock. Wella a one hour rated wall. C cda Sawhorse 123
Learn MoreFor Fire Resistance details and construction methods, refer to UL Design #U415 System A and the USG installation instructions. Two-Hour Cavity Shaft Wall (Non-
Learn MoreIn addition, DensGlass® Shaftliner shaftwall/stairwell assemblies For UL V473, 1 hour, apply 5/8” (15.9 mm) ToughRock® Fireguard X gypsum board or 5/8”
Learn MoreShaftwall systems are interior nonload-bearing fire rated wall assemblies that provide critical, life safety, fire-resistant protection for elevator shafts, stairwells, vertical chases and mechanical enclosures. Shaftwalls in elevators and stairwells are one of the most important wall assemblies in a building.
Learn MoreThe assemblies listed below are a small sample of the UL Designs in which USG shaft wall systems can be used. For more details on fi re-rated assemblies, see USG literature SA926, Shaft Wall Systems. SSA926S_08.indd 3A926S_08.indd 3 99/13/07 1:33:52 PM/13/07 1:33:52 PM
Learn More4/26 · Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. U499 April 26, Nonbearing Wall Rating — 1 Hr. 1. Channel Track — "J" -shaped channel, 2-1/2 in. deep with unequal legs of 1 in. and 2
Learn MoreMeet exterior wall system requirements Exterior wall assemblies are designed to resist the impacts of fire, wind, rain, hail, extreme temperatures and sound, and be energy efficient, attractive and much more. We understand these challenges. We provide testing, inspection, and certification solutions for exterior wall assemblies.
Learn MoreElevator installation before, during or after 2 HOUR FIRE RATED. UL DESIGN U415. 3 1/2”. SHAFT SIDE. OFFICE SIDE. GYPSUM SHAFT WALL SYSTEMS
Learn MoreFire-resistance ratings have long been used by UL and the building codes to Wall Assembly — The 1 hr or 2 hr fire rated gypsum board/steel stud wall
Learn MoreUL Design U469 - 1 Hour Wall Assembly Documents (1) Add to Package Installation Instructions - UL Design U469 - 1 Hour Wall Assembly (96 Kb, 5pg) System Package Hide Steel Studs "C-H"
Learn MoreFind resources and details for UL rated wall systems with the required STC and fire ratings for your project. UL Wall Assemblies BIM - Revit Library Transparency Catalog > NAIMA 3E
Learn MoreA 2-hour fire-resistive, non-load bearing non-combustible partition designed to enclose shaftwalls, containing elevators, ducts, piping, air shafts and similar construction applications. System consists of 1" shaftliner panels supported by 2-1/2", 4" or 6" C-T studs and faced on one side with two layers of 1/2" Type C or 5/8" Type X gypsum board.
Learn MoreThe Cavity Shaft Wall System includes components that provide the strength to withstand lateral loads and fire protection necessary for walls that enclose elevator shafts, stairwells and other vertical shafts. The system includes gypsum liner panels, gypsum panels and cement board, interior finishing products and framing components. Main Features
Learn MoreIs the Horizontal Shaft Wall UL tested? While not tested by UL, the system has been tested for fire and is covered for use throughout the United States. The fire test number is WHI 495-PSH-0154/0167 and report number is AER-09038 available at www.p-e-i.com.
Learn MoreQ: Can you explain the concept behind the wall assemblies The area separation wall consists of two layers of 1 in. thick gypsum liner
Learn More2 Hour Wall with (2) layers 5/8" Type X + (1) 1" Shaft Liner · Dead Load of assembly ONLY is considered. · Not designed to carry any Live Loads, Mechanical
Learn MoreFind resources and details for UL rated wall systems with the required STC and fire ratings for your project. Products Products > Pipe Insulation. Batts. Pipe and Tank . Blown-in Insulation. Board. UL Wall Assemblies BIM - Revit Library Transparency Catalog > NAIMA 3E Plus FAQs Technical Support
Learn MoreAssembly Rating — 1 HR. Nonbearing Wall Gypsum Board* — 1 in. thick gypsum wallboard liner panels, supplied in nominal 24 in. or 600 mm
Learn MoreFire-Rated Wall Assemblies. LP® FlameBlock® Fire-Rated OSB Sheathing is a component of the following 1-Hour Exterior Wall Assembly - UL Design No. U348
Learn MoreAttach 2" (51 mm) wide C-Track to slab at bottom of wall using suitable fasteners at a maximum of 24" (610 mm) o.c. Allow a 3/4" (19 mm) space from wood or steel stud framing on each side of the firewall. 2. Install vertical C-Track at the beginning of the wall and support as needed. 3.
Learn MoreSeveral options for 1- and 2-hour fire resistance-rated, wood-frame wall assemblies that could be useful for shafts are presented below. 1-Hour Single Wall UL U305 GA WP 3510 UL U311 IBC
Learn MoreFire-Rated Assemblies 3 USG Shaft Wall Systems 09 20 00/USG BuyLine 2425 1 Hour Fire-rated Construction Non-loadbearing Acoustical Performance Construction Detail Description Test Number STC Test Number wt. 8 † 5/8 SHEETROCK® brand FIRECODE® Core gypsum UL
Learn MoreUL Assemblies / Wall / UL U314 UL U314 Interior Partitions, Wood Stud (Load-Bearing) Stc 0 Fire Rating 1 Hour System Thickness 4-3/4" PDF (247.73 KB PDF ) REVIT (1.97 MB RVT)
Learn MoreWall Assemblies; Floor-Ceiling Assemblies; Roof-Ceiling Assemblies; Design Details; UL Type Designations; Frequently Asked Questions; Acoustical Ceilings Performance Substrate; Sealant Fire Tests; Material Estimators Material Estimators. Shaft Wall 1-Hr. AER-09038. More; Need Help?
Learn More1" USG Sheetrock® Brand Gypsum Liner Panels ASSEMBLY. USG Shaft Wall Systems | 4 UL fire resistance Classifications for one- to four-hours.
Learn MoreSecond, choose the type of design you are seeking (example – Walls/Partitions (steel framed), Floor/Ceiling (wood framed), etc.) Or search by the assembly number (UL design, or Gypsum Association file number) Then click on the Search button, and your results will be displayed below. 1-800-545-6302 ext. 5607 [email protected]
Learn MoreHourly Rating: 2-hour. Fire Test Reference: GA WP 1955. Area Separation Wall. Two layers 1” (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner